[HTML][HTML] Evaluation after cochlear implant surgery: Correlation of clinical outcome and imaging findings using flat-detector CT
A Stock, V Bozzato, SP Kloska, A Bozzato… - Clinical …, 2021 - Springer
… of electrode array position in every case [9]. Due to its superior spatial resolution, flat-detector
computed tomography (… to detect scalar dislocation despite the higher resolution of FDCT. …
computed tomography (… to detect scalar dislocation despite the higher resolution of FDCT. …
Improved cochlear implant electrode localization using coregistration of pre‐and postoperative CT
PJ Farnsworth, JC Benson, AM Nassiri… - Journal of …, 2023 - Wiley Online Library
… for scalar location of electrodes tip (± scalar translocation), tip fold … 64-slice multidetector
computed tomography with micro… position of the cochlear implant electrode array. Otol Neurotol. …
computed tomography with micro… position of the cochlear implant electrode array. Otol Neurotol. …
Use of Cone Beam Computed Tomography to Assess Cochlear implant Electrode position with Correlation to Performance
M Bassiouni, M Talaat, M Khaled… - Egyptian Journal of Ear …, 2021 - journals.ekb.eg
… In this study, we used CBCT for assessment of scalar location, … Scalar localization of the
electrode array after cochlear implantation: clinical experience using 64-slice multidetector …
electrode array after cochlear implantation: clinical experience using 64-slice multidetector …
[HTML][HTML] Review on cochlear implant electrode array tip fold-over and scalar deviation
A Dhanasingh, C Jolly - Journal of Otology, 2019 - Elsevier
… Determine the occurrence rate of cochlear implant (CI) electrode tip fold-over and electrode
scalar deviation as reported in patient … position” and “Cochlear electrode scalar location”. …
scalar deviation as reported in patient … position” and “Cochlear electrode scalar location”. …
Potential insertion complications with cochlear implant electrodes
A Ishiyama, F Risi, P Boyd - Cochlear Implants International, 2020 - Taylor & Francis
… reporting scalar position of intracochlear electrode arrays have … by postoperative cone beam
computerized tomography (… of high-resolution 64-slice multi-detector CT images, and some …
computerized tomography (… of high-resolution 64-slice multi-detector CT images, and some …
Comparative analysis of robotics-assisted and manual insertions of cochlear implant electrode arrays
AD Claussen, SB Shibata, CR Kaufmann… - Otology & …, 2022 - ingentaconnect.com
… due to electrode array insertion, such as scalar translocation, … same spatial positioning
with the electrode array removed. … Recent high-resolution computed tomographic imaging of …
with the electrode array removed. … Recent high-resolution computed tomographic imaging of …
[PDF][PDF] Cochlear implantation: post-operative assessment with image fusion
S Sipari - 2020 - erepo.uef.fi
… Scalar localization of the electrode array after cochlear implantation: clinical experience
using 64-slice multidetector computed tomography. Otology & Neurotology: Official Publication …
using 64-slice multidetector computed tomography. Otology & Neurotology: Official Publication …
Assessment of frequency-place mismatch by flat-panel CT and correlation with cochlear implant performance
D Zanetti, G Conte, F Di Berardino, FL Russo… - Otology & …, 2021 - journals.lww.com
… of the intrascalar localization of electrodes array has been … , as well as in some studies in
cochlear implant recipients (16,20–… of the array in all our patients: it is well known that the scalar …
cochlear implant recipients (16,20–… of the array in all our patients: it is well known that the scalar …
Misplaced Cochlear Implant Electrodes Outside the Cochlea: A Literature Review and Presentation of Radiological and Electrophysiological Findings
LL Cheung, J Kong, PY Chu, H Sanli… - Otology & …, 2022 - ingentaconnect.com
… on cochlear implant electrode array tip fold-over and scalar … 64-slice and new generation
192-slice multi-detector computed … Cone beam computed tomography, a low-dose imaging …
192-slice multi-detector computed … Cone beam computed tomography, a low-dose imaging …
[PDF][PDF] MA van der Jagt, JJ Briaire, S Boehringer, BM Verbist, JHM Frijns
S Boehringer - … cochlear morpholog and the implanted … - scholarlypublications …
… the intra-scalar position of electrode arrays after cochlear implantation. This method …
implantation: clinical experience using 64-slice multidetector computed tomography. Otol Neurotol. …
implantation: clinical experience using 64-slice multidetector computed tomography. Otol Neurotol. …