[HTML][HTML] Evaluation after cochlear implant surgery: Correlation of clinical outcome and imaging findings using flat-detector CT

A Stock, V Bozzato, SP Kloska, A Bozzato… - Clinical …, 2021 - Springer
… of electrode array position in every case [9]. Due to its superior spatial resolution, flat-detector
computed tomography (… to detect scalar dislocation despite the higher resolution of FDCT. …

Improved cochlear implant electrode localization using coregistration of pre‐and postoperative CT

PJ Farnsworth, JC Benson, AM Nassiri… - Journal of …, 2023 - Wiley Online Library
… for scalar location of electrodes tip (± scalar translocation), tip fold … 64-slice multidetector
computed tomography with micro… position of the cochlear implant electrode array. Otol Neurotol. …

Use of Cone Beam Computed Tomography to Assess Cochlear implant Electrode position with Correlation to Performance

M Bassiouni, M Talaat, M Khaled… - Egyptian Journal of Ear …, 2021 - journals.ekb.eg
… In this study, we used CBCT for assessment of scalar location, … Scalar localization of the
electrode array after cochlear implantation: clinical experience using 64-slice multidetector

[HTML][HTML] Review on cochlear implant electrode array tip fold-over and scalar deviation

A Dhanasingh, C Jolly - Journal of Otology, 2019 - Elsevier
… Determine the occurrence rate of cochlear implant (CI) electrode tip fold-over and electrode
scalar deviation as reported in patient … position” and “Cochlear electrode scalar location”. …

Potential insertion complications with cochlear implant electrodes

A Ishiyama, F Risi, P Boyd - Cochlear Implants International, 2020 - Taylor & Francis
… reporting scalar position of intracochlear electrode arrays have … by postoperative cone beam
computerized tomography (… of high-resolution 64-slice multi-detector CT images, and some …

Comparative analysis of robotics-assisted and manual insertions of cochlear implant electrode arrays

AD Claussen, SB Shibata, CR Kaufmann… - Otology & …, 2022 - ingentaconnect.com
… due to electrode array insertion, such as scalar translocation, … same spatial positioning
with the electrode array removed. … Recent high-resolution computed tomographic imaging of …

[PDF][PDF] Cochlear implantation: post-operative assessment with image fusion

S Sipari - 2020 - erepo.uef.fi
Scalar localization of the electrode array after cochlear implantation: clinical experience
using 64-slice multidetector computed tomography. Otology & Neurotology: Official Publication …

Assessment of frequency-place mismatch by flat-panel CT and correlation with cochlear implant performance

D Zanetti, G Conte, F Di Berardino, FL Russo… - Otology & …, 2021 - journals.lww.com
… of the intrascalar localization of electrodes array has been … , as well as in some studies in
cochlear implant recipients (16,20–… of the array in all our patients: it is well known that the scalar

Misplaced Cochlear Implant Electrodes Outside the Cochlea: A Literature Review and Presentation of Radiological and Electrophysiological Findings

LL Cheung, J Kong, PY Chu, H Sanli… - Otology & …, 2022 - ingentaconnect.com
… on cochlear implant electrode array tip fold-over and scalar64-slice and new generation
192-slice multi-detector computed … Cone beam computed tomography, a low-dose imaging …

[PDF][PDF] MA van der Jagt, JJ Briaire, S Boehringer, BM Verbist, JHM Frijns

S Boehringer - … cochlear morpholog and the implanted … - scholarlypublications …
… the intra-scalar position of electrode arrays after cochlear implantation. This method …
implantation: clinical experience using 64-slice multidetector computed tomography. Otol Neurotol. …